Voyager® Pro Precision Balances

 
The Voyager Pro features numerous application modes such as differential weighing and density determination and an applications library to store and quickly recall past procedures. An ultra-simple and innovative user interface allows for effortless set up and operation - - essentially eliminating the need for any preliminary training. Additional standard features such as scroll down menus, on screen text prompts, high-resolution LCD display, five operation languages, and selectable environmental setting, make the Voyager Pro one of the most easy to use yet most accurate and advanced balance in its category. Other standard features include RS232 port for connectivity, GLP protocol, selectable auto-print settings, and an integral weigh below hook. To further protect your investment, Voyager Pro is designed with a spill channel and includes a display in-use cover. The Voyager Pro is manufactured to ISO 9001:2000 quality assurance specifications.
 
Key Features
  • Superior Draft Shield - A large 3 - door draft shield is standard on all Voyager Pro Analytical and Precision balances with a 0.1/1 mg readability. The draft shield design provides optimum draft protection from wind currents for superior balance stability and reproducibility even in challenging environments. The large chamber can accommodate larger vessels and the removable side doors mike it easy to clean
  • Automatic Calibration - Voyager Pro's standard AutoCal™ calibration feature automatically calibrates the balance when it senses a temperature change sufficient enough to affect weighing accuracy. This feature assures accuracy while saving operational time.
  • Protective Cover - Voyager Pro's standard in-use cover is replaceable and protects the display from harsh environments or spills that can ruin the balance.
  • Large Brilliant Display - Voyager Pro's high-resolution dot matrix display with backlight enhances viewing in any environment and has adjustable contrast and brightness controls. The display illustrates the weighing results with large numeric indicators and features user definable text fields to illustrate only the information you want! The display also illustrates secondary units time and date.
  • Communications Port with GLP/GMP Data Output - The standard RS232 communication port offers connectivity and it's GLP/GMP data output capability prints time, date, balance, project, user id, calibration information and weighing information. Simply connect your Voyager Pro to the optional Ohaus SF42 accessory printer and full traceability of weighing procedures is achieved without the need for sophisticated, expensive peripherals.
  • Innovative Software - Voyager Pro's innovative user interface combines a dot matrix display with scroll down menus, software prompts and 5 operating languages. Balance setup and use is made simple and easy to follow with no training required. The three application-specific soft-keys allow direct access to features such as calibration, units, sample size and reference information at the touch of a button. An applications library stores and quickly recalls past procedures eliminating the need to re-establish application parameters.

 

Precision Balance Specifications
Capacity (g) 210 410 610 100 / 410 610 2100 4100 6100 1000 / 4100 4100 6100 8100
Readability (mg)

0.001

0.001 / 0.01 0.01 0.01 / /0.1 0.1
Repeatability (Std.) (mg) 0.0005 0.0015 0.0005 / 0.005 0.005 0.01 0.01 / 0.05 0.05
Linearity (mg) ±0.002 ±0.002 / 0.005 ±0.02 ±0.04 ±0.02 / 0.05 0.1
Stabilization Time (s) 3
Pan Size (in/cm) 4.7 / 12 dia. 6.8 x 6.8 / 17.2 x 17.2 w/windshield
Dimensions W x H x D (in/cm) 8.3 x 13.8 x 13.8 / 21 x 35 x35 8.5 x 4 x 13.8 / 21.5 x 10.3 x 35
Net Weight (lb/kg) 13.2 / 6 11 / 5
Weighing Units gram, milligrams, ounce, ounce troy, carat, pennyweight, Hong Kong Tael, Singapore Tael, Taiwan Tael, mommes, grain, tical, Newton, custom
Application Modes Statistics, Formulation, Differential Weighing, SQC, Density Deterination, Pipette Calibration, Parts Counting, Animal Weighing, Check Weighing, Percent Weighing, Filling, Gross-Net-Tare Weighing
Features Applications Library, RS232 Port, Auxiliary Display Port, GLP Protocol, Selectable Operating Language, Selectable Display Information Settings, Selectable Environmental Settings, Selectable Auto-Print Settings, Integral Weigh Below Hook, Contrast & Brightness Control, Protective In-Use Cover.
Tare Range

Full Capacity by Subtraction

Operation Temperature Range

50° to 104°F / 10° to 40°C

Power Requirements 100-120 V AC, 220-240 V AC, 50/60 Hz
Calibration Internal / External
Display Type

LCD Dot Matrix w/Backlight

Display Size 240 x 128 pixels
Item Number VP213CN VP413CN VP613CN VP413DNC* VP612CN VP2102CN VP4102CN VP6102CN VP4102DCN* VP4101CN VP6101CN VP8101CN